Primary Flare or Primary Taper

Hole Qualities UT tolerance (ø0.3 mm) : 0.006 mm or less
  If they are symmetrical, there is no serious effect on registration accuracy.
   
Primary Flare
Primary Taper
Countermeasure (Setting of drill point)
1. Adjust drill position and cross hairlines
  Primary Flare
  Reposition the drill bit slightly to the left of the cross hairline.
Adjust cross hairline after grinding.
  Primary Taper
  Reposition the drill bit slightly to the right of the cross hairline.
Adjust cross hairline after grinding.
 
2. Adjust the magnification of microscope to recognize drill position well.
 
3. Tighten fixture screws not to move the cross hairline.
  -. Tighten the microscope height adjust screw
-. Tighten the microscope lens screw
-. Reduce the amount of shock absorber extension.
 
4. Adjust the universal joint (Correcting runout)
 